User Guide
FMTx2.0 Si4713 visual inspection troubleshooting
Troubleshooting flow
Checking validity of signals
Please refer to Access to signals figure as a reference. Generally all power supply levels and clocks willbe
consistent. Signals on the analogue audio input pins (RIN & LIN – pins 15 and 16 respectively) will be
dependant on the audio content being injected to the device. During the audio self test (initiated from
Phoenix) it is possible to monitor these pins and check that the DSP generated 1KHz tones can be seen at
some point during the test. Check that the signals are clean and that no obvious distortion can be seen such
as clipping of the signals. Typical maximum swing of these tones will be ~636mV peak to peak. The maximum
swing may vary between Nokia handsets but for the FMTx 2.0 implementation, the swing should not be
greater than the aforementioned value.
FMTx2.0 troubleshooting faults
Possible faults
Expected fault reports relating to the FMTx 2.0 implementation may consist of one or more of the following;
RM-348; RM-349; RM-350
FMTx 2.0 Troubleshooting
Issue 2 COMPANY CONFIDENTIAL Page 7 –13
Copyright © 2008 Nokia. All rights reserved.