User Guide

Voltage Voltage [V] Condition
Vmstr- 1.9 ± 0.1 On to off
SW Shutdown Voltages
Sw shutdown 3.15 In call
Sw shutdown 3.3 In idle
Min Operating Voltage
Vcoff+ 2.9 ± 0.1 Off to on
Vcoff- 2.6 ± 0.1 On to off
Power key and system power-up
Power key is in end key. When the battery is placed in the phone the power key circuits are energized. When
the power key is pressed, the system boots up (if an adequate battery voltage is present).
Power down can be initiated by pressing the power key again (the system is powered down with the aid of
SW). The power key is connected to EM ASIC N2200 (AVILMA) via PWRONX signal.
The power key may be disabled in certain charging cases.
RM-412; RM-413
System Module and User Interface
Page 6 –10 COMPANY CONFIDENTIAL Issue 1
Copyright © 2009 Nokia. All rights reserved.