User Guide
Vibra circuitry
The vibra circuitry is used for the vibra-alarm function.
The vibra motor is connected to the EM ASIC (N2200) VibraP and VibraN Pulse Width Modulated (PWM) outputs.
Figure 101 Vibra circuitry
System connector
System connector provides a fully differential 4–wire stereo line-level output connection and fully differential
2-wire mono line-level or microphone level input connection.
The handsfree driver in EM ASIC (N2200) is meant for the headset.
The earpiece and headset signals are multiplexed so that the outputs cannot be used simultaneously.
Figure 102 External audio connector
Table 17 Audio connector pin assignments
Pin #/ Signal
name
Signal
description
Spectral range Voltage/
Current levels
Max or
nominal serial
impedance
Notes
1/ Charge V Charge DC 0-9V/ 0.85A
2/ GND Charge GND - 0.85A 100mΩ (PWB+
conn.)
3/ ACI ACI 1kbits/s Digital 0 / 47Ω Insertion &
removal
detection
2.5-2.78V
RM-10;RM-24
Nokia Customer Care System Module
Page 9 –28 COMPANY CONFIDENTIAL Issue 1
Copyright © 2006 Nokia. All rights reserved.