5. Setup the signal generator to correspond the values in the
RX AGC Calibration
pop-up window and click
OK.
Frequency: 2141MHz
Level: –51 dBm + cable and adapter attenuations
Modulation: FM
Deviation: 500 kHz
Modulation frequency: 50 kHz
6. Check that the
Rx chain
value in
Tuning Results
is within the limits presented in the following table.
Min Typ Max Unit
RX chain -6 1.5... 3.5 6 dB
Low freq -5 -0.7... 4.0 5
High freq -5 -0.7... 4.0 5
i If the Rx gain is acceptable, click Yes to save the results to the phone.
7. To close the
Rx AGC Alignment
window, click Close.
Rx band response calibration (WCDMA)
Context
There is a band rejecting filter for each WCDMA Rx band between the front end LNA and the mixer of an RF
ASIC. The amplitude ripple caused by this filter causes ripple to the RSSI measurement and therefore Rx band
response calibration is needed.
The Rx band response calibration can be done in two different ways. If the signal generator used supports
frequency sweep table, the calibration can be done as a part of the Rx calibration. If there is no support for
the frequency sweep table , it is possible to calibrate all necessary frequencies one by one.
The first set of steps shows how to perform the calibration without the signal generator sweep feature. The
alternative steps give instructions how to perform the calibration if the signal generator supports frequency
sweeps, and the calibration can be performed within the Rx AGC calibration.
RM-10;RM-24
RF Troubleshooting and Manual Tuning Guide Nokia Customer Care
Issue 1 COMPANY CONFIDENTIAL Page 7 –41
Copyright © 2006 Nokia. All rights reserved.