User Guide
Normally a spectrum analyser is used as measurement equipment.
Note: The maximum input power of a spectrum analyser is +30 dBm.
To prevent any damage, it is recommended to use 10 dB attenuator on the spectrum analyzer input.
4. Set Tx on.
i Set the phone module to the test jig and start
Phoenix service software
.
ii Initialize connection to the phone. (With FPS-8 use FBUS driver when using DAU-9S and COMBOX driver).
iii From the File menu, choose product: File -> Choose Product -> xx-x* (* = type designator of the
phone).
iv From the toolbar, set Operating mode to “Local”.
Alternative steps
• GSM850/EGSM900/GSM1800/GSM1900 troubleshooting
i From the Testing menu, activate the
RF Controls
window: Testing -> GSM -> RF Controls .
ii In the
RF Controls
window:
• Select band "GSM850" or “GSM900” or “GSM1800” or “GSM1900” (Default = “GSM900”).
• Set Active unit to “Tx” (Default = “Rx”).
• Set Operation mode to “Burst” (Default = “Burst”).
• Set Tx data type to “All1” (Default = “All1”).
• Set Rx/Tx channel to 190 on GSM850 or 37 on GSM900 band or 700 on GSM1800 band or 661 on
GSM1900 (Defaults).
• Set Edge to “Off” (Default).
• Set Tx PA mode to “Free” (Default).
• Set power level to 5 (Default = 19) on GSM850/GSM900 or to 0 (Default = 15) on GSM1800/GSM1900.
RM-10;RM-24
Nokia Customer Care RF Troubleshooting and Manual Tuning Guide
Page 7 –16 COMPANY CONFIDENTIAL Issue 1
Copyright © 2006 Nokia. All rights reserved.