User Guide

4. To complete the installation procedure, click Finish .
Figure 23 Finish flash update
Next actions
FPS-10 flash prommer must be updated using
Phoenix
.
Updating FPS-10 flash prommer software
Steps
1. Start
Phoenix
service software, and log in.
2. Choose the correct connection for your flash prommer: FileManage Connections...
3. Choose FlashingPrommer maintenance .
4. To update the FPS-10 software, click Update, and select the appropriate file or
fpsxupd.ini
(for FPS-10)
from
C:\Program Files\Nokia\Phoenix\Flash
.
Figure 24 Flash directory window
RM-208
Nokia Customer Care Service Software Instructions
Page 3 –22 COMPANY CONFIDENTIAL Issue 1