5. Click Start.
The current values are shown in the
Tuned Values
pane.
6. Click Tune.
7. Connect the spectrum analyzer to the terminal, and set it to Channel Mid frequency. Use spectrum
analyzer’s RMS detector and depending on spectrum analyzer use 30 kHz video bandwidth.
8. Read the values from the power meter and enter them to Middle power level fields in the
Measured Power Levels pane.
9. Click Next.
10. Switch the power meter to Channel Low frequency.
11. Read the values from the power meter, and enter them to Low power level fields.
12. Switch the power meter to Channel High frequency.
13. Read the values from the power meter, and enter them to High power level fields.
14. Click Next.
15. Click Calculate.
The tuned values are shown in the
Tuned Values
pane in the
New
column.
16. Check that the tuned values are within the limits presented in the following table. If they are OK, click
Yes.
RM-208
RF Troubleshooting and Manual Tuning Guide Nokia Customer Care
Issue 1 COMPANY CONFIDENTIAL Page 7 –41