18. Select the
Algorithm
mode tab.
19. Write the target power level 28 dBm to the
Start level
box and check the Max power limit check box
(detector calibration check). Write "1" to
Sequence
box.
20. Setup the spectrum analyzer with the following settings:
Table 18
Center frequency 1950.0 MHz
Span 0 Hz
Reference level offset Cable attenuations + adapter
attenuation
Reference level 28 dBm or -20 dBm depending
on the level measured
Input attenuation Automatic
Resolution bandwidth 5 MHz
Video bandwidth 5 MHz (depending on spectrum
analyzer use 30 kHz VBW)
Sweep time 5 ms
Detector RMS detector
Average No
Trigger level Video 0 dBm or -45 dBm
21. Measure the WCDMA output power. It should be around 23.5 dBm.
22. Click RF Stop and uncheck the Max power limit check box.
RM-208
RF Troubleshooting and Manual Tuning Guide Nokia Customer Care