12. Measure the power levels with a marker and fill them to the table starting from the highest one.
Measured power levels must be monotonously decreasing.
Figure 47 High burst measurement
13. In the
High Burst
pane, click Calculate.
14. Check that the calculated values are within the limits specified in the following table:
Min Max
C0-high -0.5 5
C1-high -50 50
C2-high 400 900
C0-mid -0.7 0.7
C1-mid 0 50
C2-mid 400 900
C0-low -4 4
C1-low -400 440
C2-low -10000 15000
Det-k 100 220
Det-b 0 150
15. To save the coefficients to the phone, click Write.
16. To close the
Tx AGC & Power Detector
window, click Close.
17. Choose TestingWCDMA Tx Control.
RM-208
Nokia Customer Care RF Troubleshooting and Manual Tuning Guide