User Guide

2. Choose TuningWCDMATX AGC And Power Detector Tuning.
3. Click Start.
4. In the
Wide Range
pane, click Tune (the leftmost Tune button).
5. Set up the spectrum analyzer in the following way:
6. After setting the spectrum analyzer, click OK.
7. Measure the power levels with a marker and fill them to the table starting from the highest one. The
lowest power level filled to the table should be at least <-50 dBm. Measured power levels must be
monotonously decreasing.
RM-208
Nokia Customer Care RF Troubleshooting and Manual Tuning Guide
Page 7 –36 COMPANY CONFIDENTIAL Issue 1
Copyright © 2007 Nokia. All rights reserved.