User Guide

Figure 43 RF Controls window
GSM TX output power measurement
Power meter or spectrum analyzer is used for power measurement. Spectrum analyzer settings see
section “Tx power level tuning (GSM)”.
Power level value (dBm) for selected band and power level is read from the measurement equipment.
WCDMA troubleshooting
i From the Testing menu, activate the
Tx Control
window:Testing -> WCDMA -> Tx Control .
ii In the
Tx Control
window:
Select the
Algorithm mode
tab.
Set Start level to “0” dBm (Default = “0”).
Set Step size, Step count and Sequence to “0” (Default = “0”).
Set Scrambling code class to “LONG” (Default = “LONG”).
Set Scrambling code to “16” (Default = “16”).
Set DPDCH Code number to “0”, Code class to “2” and Weight to “15” (Defaults).
Set DPCCH Code number to “0”, Code class to "2" and Weight to “8” (Defaults).
Set Channel to 9750.
Check the "DPDCH enabled" checkbox (Default).
RM-208
RF Troubleshooting and Manual Tuning Guide Nokia Customer Care
Issue 1 COMPANY CONFIDENTIAL Page 7 –13
Copyright © 2007 Nokia. All rights reserved.