User Guide
12. Measure the power levels with a marker.
Take the first measurement from 250 us after the trigger, the second after 750 us, the third after 1250
us and so on for every 500 us until the table is filled.
Figure 25 High burst measurement
13. In the
High Burst
pane, click Calculate.
14. Check that the calculated values are within the limits specified in the following table:
Min Max
C0-high -0.5 5
C1-high -50 50
C2-high 400 900
C0-mid -0.7 0.7
C1-mid 0 50
C2-mid 400 900
C0-low -4 4
C1-low -400 440
C2-low -10000 15000
RM-437; RM-449; RM-450
RF troubleshooting
Page 4 –34 COMPANY CONFIDENTIAL Issue 1