User Guide
Figure 67 Functional block diagram
The application processor takes care of processing application SW and handles the UI SW. It consists of
OMAP3.3 and peripheral subsystems like display- and keyboard driver blocks.
Absolute maximum ratings
Signal Min Nom Max Unit Notes
Battery voltage (idle) -0.3 +4.5 V Battery voltage maximum value is
specified during charging is active
Battery voltage (Call) +3.2 +4.3 V Battery voltage maximum value is
specified during charging is active
Charger input voltage -0.3 +20 V
Back-Up supply voltage 0 2.5 2.6 V Maximum capacity of the backup
power supply assumed to be 10 µAh.
Phone modes of operation
Mode Description
NO_SUPPLY (dead) mode means that the main battery is not present or its voltage is too low (below
N2200 master reset threshold) and that the back-up battery voltage is too low.
BACK_UP The main battery is not present or its voltage is too low but back-up battery voltage is
adequate and the 32 kHz oscillator is running (RTC is on).
RM-49
Nokia Customer Care System Module
Page 8 –6 COMPANY CONFIDENTIAL Issue 1
Copyright © 2006 Nokia. All rights reserved.