User Guide
There is a band rejecting filter for each WCDMA Rx band between the front end LNA and the mixer of an RF
ASIC. The amplitude ripple caused by this filter causes ripple to the RSSI measurement and therefore Rx band
response calibration is needed.
The Rx band response calibration can be done in two different ways. If the signal generator used supports
frequency sweep table, the calibration can be done as a part of the Rx calibration. If there is no support for
the frequency sweep table , it is possible to calibrate all necessary frequencies one by one.
The first set of steps shows how to perform the calibration without the signal generator sweep feature. The
alternative steps give instructions how to perform the calibration if the signal generator supports frequency
sweeps, and the calibration can be performed within the Rx AGC calibration.
Steps
1. Connect the GSM connector of the module jig to a signal generator.
2. From the Operating mode drop-down menu, set mode to Local.
3. Choose Tuning→WCDMA→Rx Calibration .
4. Click Start and Tune.
RM-49
Nokia Customer Care RF Troubleshooting and Manual Tuning Guide
Page 7 –32 COMPANY CONFIDENTIAL Issue 1
Copyright © 2006 Nokia. All rights reserved.