6. Set the spectrum analyzer for power level tuning:
Table 10 Spectrum analyzer settings: EDGE OFF tuning
Frequency channel frequency (897.4MHz GSM900,
1747.8MHz GSM1800, 1880MHz GSM1900)
Span 200 kHz
Sweep time 3s
Trigger Video triggering: Free run
Resolution BW 1 MHz
Video BW 3 kHz
Reference level offset sum cable attenuation with module jig
attenuation
Reference level 35dBm
Detector Max Peak
A power meter with a peak power detector can be also used. Remember to take the attenuations into
account!
7. Adjust power levels 5, 15 and 19 to correspond the
Target dBm
column by pressing + or – keys.
Check that the coefficient values are within the limits specified in the following table.
RM-49
Nokia Customer Care RF Troubleshooting and Manual Tuning Guide
Page 7 –30 COMPANY CONFIDENTIAL Issue 1
Copyright © 2006 Nokia. All rights reserved.