Temperature sensor calibration is done in room temperature, in which offset caused by the ASIC variation
and AD-converter are nullified.
The module is able to do this calibration by itself, no external equipment is needed.
The temperature of the module and components must be 23 +/-2 degrees.
Steps
1. From the Operating mode drop-down menu, set mode to Local.
2. Choose TuningTemperature Sensor Calibration .
3. Click Tune.
Table 6 Temperature sensor calibration tuning limits
Min Typ Max Unit
-20 -4 20 V
4. To save the calibration values, click Write.
5. To finish the calibration, click Close.
GSM receiver tunings
Rx calibration (GSM)
Context
Rx Calibration is used to find out the real gain values of the GSM Rx AGC system and tuning response of the
AFC system (AFC D/A init value and AFC slope)
Steps
1. Connect the GSM connector of the module jig to a signal generator.
2. Start
Phoenix
service software.
3. Choose FileScan Product.
4. From the Operating mode drop-down menu, set mode to Local.
5. Choose TuningGSMRx Calibration.
RM-49
RF Troubleshooting and Manual Tuning Guide Nokia Customer Care
Issue 1 COMPANY CONFIDENTIAL Page 7 –19