Table 5 Rf channel filter calibration tuning limits
Min Typ Max
Tx filter 0 10 31
Rx filter 0 16 31
Steps
1. From the Operating mode drop-down menu, set mode to Local.
2. Choose Tuning→Rf Channel Filter Calibration.
3. Click Tune.
4. To save the values to the PMM (Phone Permanent Memory) area, click Write.
5. To end the tuning, click Close.
Results
Figure 64 Rf channel filter calibration typical values
PA (power amplifier) detection
Context
The PA detection procedure detects which PA manufacturer is used for phone PAs.
If a PA is changed or if the permanent memory (PMM) data is corrupted, PA detection has to be performed
before Tx tunings.
Steps
1. From the Operating mode drop-down menu, set mode to Local.
2. Choose Tuning→PA Detection .
3. Click Tune.
4. Check that the detected PA manufacturers are corresponding to the actual chips on the board.
5. To end the procedure, click Close.
Temperature sensor calibration
Context
There is a temperature sensor integrated into one of the device ASICs. The ASIC provides DC-voltage, which
is temperature dependent.