User Guide

Figure 63 BT antenna
RF tunings
Introduction to RF tunings
Only perform RF tunings if:
one or more of the RF components is changed
A flash memory chip is changed or otherwise corrupted.
Caution: RF calibration is always performed with the help of a product-specific module jig, never
with an RF coupler. Using an RF coupler in the calibration phase results in a complete mistuning of
the RF side.
Important: After RF component changes, always use autotuning. Manual tunings are only required
in rare cases.
Cable and adapter losses
RF cables and adapters have some losses. They have to be taken into account when the phone is tuned. As
all the RF losses are frequency dependent, you have to be very careful and understand the measurement
setup. The following table presents the RF attenuations of a product-specific module jig:
RM-49
Nokia Customer Care RF Troubleshooting and Manual Tuning Guide
Page 7 –14 COMPANY CONFIDENTIAL Issue 1
Copyright © 2006 Nokia. All rights reserved.