User Guide

Note: The maximum input power of a spectrum analyser is +30 dBm.
To prevent any damage, it is recommended to use 10 dB attenuator on the spectrum analyzer input.
4. Set Tx on.
i Place the phone module to the test jig and start
Phoenix
service software.
ii Initialize connection to the phone (with FPS-10 use FBUS when using a DAU-9S cable and a COMBOX
driver).
iii Choose FileOpen Productxx-x* (* = type designator of the phone) or FileScan Product. .
iv From the toolbar, set Operating mode to Local.
Alternative steps
EGSM900/GSM1800/GSM1900 troubleshooting
i Choose TestingGSMRF Controls.
ii In the
RF Controls
window:
Choose Band: GSM900 or GSM1800 or GSM1900 (Default = GSM900).
Set Rx/Tx channel in the following way:
GSM900: 37
GSM1800: 700
GSM1900: 661
Set Active unit to Tx (Default = Rx).
Set Operation Mode to Burst (Default = Burst).
Set Edge to Off (Default).
Set Tx Data Type to All 1 (Default = All 1).
Set Tx PA Mode to High (Default).
Set Tx Power Level in the following way:
GSM900: 5 (Default = 19)
GSM1800: 0 (Default = 15)
GSM1900: 0 (Default = 15)
RM-49
Nokia Customer Care RF Troubleshooting and Manual Tuning Guide
Page 7 –10 COMPANY CONFIDENTIAL Issue 1
Copyright © 2006 Nokia. All rights reserved.