User Guide
Issue 1 09/04 COMPANY CONFIDENTIAL 44
Copyright © 2004 Nokia. All Rights Reserved.
RA-2/3
3 - Service Software Instructions Nokia Customer Care
Service Tool Concept for RF Tuning Operations
• All RF tuning operations must be carried out in the MJ-19 module jig.
• Power to MJ-19 must be supplied from an external DC power supply, not from the
FPS-8 prommer.
• MJ-19 input voltages:
Maximum + 12 VDC
Nominal input for RF tunings is +? V DC
Minimum + 4V DC
• Remember the cable attenuation when setting required RF levels
Figure 1: RF tuning setup
Item Service accessory Type Product code
1 Module jig MJ-19 0780372
2 DC power cable PCS-1 0730012
3 Modular cable XRF-1 0730085
4 Service Mbus cable DAU-9S 0730108
5 Software protection key PKD-1 0750018
6Service SW CD-ROM
1
2
3
4
5
6