User Guide
RAE-6/RA-4
Nokia Customer Care 3 - Service Software Instructions
53 COMPANY CONFIDENTIAL Issue 1 12/04
Copyright © 2004 Nokia. All Rights Reserved.
5. Set RF generator to required GSM1800 frequency => OK.
Tuning values and ADC readings are shown.
Table 3: Typical values and limits in (GSM1800) Rx Calibration
GSM1800 Typical value Low limit High limit
Rssi 0: 65 60 70
Rssi 1: 71 66 76
Rssi 2: 77 72 82
Rssi 3: 83 78 88
Rssi 4: 89 84 94
Rssi 5: 95 90 100
Rssi 6: 101 96 106
Rssi 7: 107 102 112
Rssi 8: 113 108 118
Rssi 9: 119 114 124
Rssi 10: 125 120 130
Rssi 11: 131 126 136
Rssi 12: 137 132 142
Rssi 13: 143 138 148
Rssi 14: 149 144 154