User Guide
Issue 1 12/04 COMPANY CONFIDENTIAL 47
Copyright © 2004 Nokia. All Rights Reserved.
RAE-6/RA-4
3 - Service Software Instructions Nokia Customer Care
RF equipment (only one of each is needed)
TX/RX:
CMU200
TX:
Agilent E4406 (VSA series transmitter tester)
Agilent E4445 (PSA series transmitter tester)
Rohde&Schwarz, FSE-family of Signal Analyzers
Rohde&Schwarz, FSIQ-family of Signal Analyzers
RX:
Agilent ESG family of RF Signal Generators
Rohde&Schwarz, SME-family of Signal Generators
Figure 7: Preferred setup environment
Figure 8: Alternative setup environment
GPIB addresses are not defined. Component finds the addresses and uses them automatical-
ly.
If several TX tuning devices are connected, this component uses Agilent (VSA or PSA). In RX
side, Agilent has highest priority.