PAMS Technical Documentation RAE-5 Series PDA 6. Service Tools Issue 1 04/02 Copyright 2002. Nokia Corporation. All Rights Reserved.
PAMS RAE-5 6.
PAMS Technical Documentation RAE-5 6. Service Tools CONTENTS -Troubleshooting Page No Module Jig MJS-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Views of MJS-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . User Guide for MJS-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Warnings: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PAMS RAE-5 6. Service Tools Technical Documentation Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of FLS-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Service Cable SCH-12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of SCH-12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D9-D9 Cable AXS-4 .
PAMS RAE-5 6. Service Tools Technical Documentation Module Jig MJS-14 The module jig MJS-4 is used for RAE-5 module testing and repairing. There are slots for each module in the jig. The jig includes connections for charger, power supply, external RF, audios and FBUS/MBUS. Slots for Memory card and SIM card are also included. This equipment is powered by a laboratory power source. Product Code Module Jig MJS-14: 0770175 Views of MJS-14 Seen from left Seen from right Seen from front Figure 1.
PAMS RAE-5 6. Service Tools Technical Documentation Seen from back Figure 2. Note: Page 6 – 6 MJS-14, the backside The nominal supply voltage for MJS-14 is +4.0 V. The supply voltage must not exceed +4.1 V.
PAMS RAE-5 Technical Documentation 6. Service Tools User Guide for MJS-14 Warnings: Power Source Do not connect negative voltage to Voltage IN -terminals. Do not connect voltages over 4,2 volts to Voltage IN -terminals. Flash Mode vs. EPOC Running -mode If you are using Wintesla service software (for flashing or for testing) do not use the ”Run EPOC” switch. EPOC software is not allowed to be running during flashing or while software resets are possible (Wintesla connected).
PAMS RAE-5 6. Service Tools Technical Documentation 1 S101: Head set detection 2 S102: Hook detection 3 S103: Accessory detection Starting Open the cover of the jig and place SIM card and microphone to their places if needed. Then place modules of RAE-5 to proper positions: first KL8 then in order JC4 (board to board adapter), UL8 (keymat on it if needed) and (keymat under if needed) DL1.
PAMS RAE-5 Technical Documentation 6. Service Tools or data transfer going to/from memory card (or serial flash). After pressing the nail down turn the source off within 5 seconds (while PDA display is blanked if cover open). Note: Check whether the SW version of the device under test supports this function (battery removal interrupt).
PAMS RAE-5 6. Service Tools Technical Documentation Signals in Board to Board Adapter JC4 Table 1.
PAMS RAE-5 6. Service Tools Technical Documentation Flash Prommer FPS-8 (Sales Pack) The Flash Prommer FPS-8 is used to update the main software of the phone. Updating is done by first loading the new MCU software from the PC to the flash prommer, and then loading the new SW from the prommer to the phone. When updating more than one phone in succession, the MCU software only needs to be loaded to the prommer once.
PAMS RAE-5 6. Service Tools Technical Documentation Calibration Unit JBE-2 Calibration Unit JBE-2 is needed for the resistance, current- and voltage calibrations of a RAE-5 Communicator. These calibrations are needed so that the charging situation would be precise enough. NOTE: The JBE-2 is also the voltage source for the BBL-3B service battery. JBE-2 is the only service equipment which can provide enough current for any service case.
PAMS RAE-5 Technical Documentation 6. Service Tools User Guide for JBE-2 Service Operations Needed equipment: a laboratory power source, a calibration unit JBE-2, a service battery BBL-3B and a service cable DAU-9C. Use the JBE-2 calibration unit as a power source for the phone. It is the only service tool which can provide needed currents in any service case. The JBE-2 is powered by a laboratory power source.
PAMS RAE-5 6. Service Tools Technical Documentation Service Car Kit HCL-1 The Service Car Kit, HCL-1 is used for RF tuning of a RAE-5 communicator. HCL-1 is modified from CRM-1 car kit. HCL-1 is used as interface between RAE-5 and service software (Wintesla) while doing RF tuning and power management. Note 1: Other needed accessories for RF tuning are Modular T adapter and DAU-9S.
PAMS RAE-5 6. Service Tools Technical Documentation User Guide for HCL-1 Connection to Service SW A service car kit HCL-1 is used with a Wintesla service software. Needed accessories are Modular-T-adapter and DAU-9S cable. With these accessories the MBUS is connected straight from the phone to the PC and the necessary level transformations are executed.. It is also possible to plug the mod8 connector straight to mod10 socket of FPS-8 prommer and control the phone through it.
PAMS RAE-5 6. Service Tools Technical Documentation Dummy Service Battery BBL-3B The Dummy Service Battery BBL-3B (with banana clips) is used in place of the communicator’s normal battery during service. The BBL-3B supplies a controlled operating voltage from FPS-8 when flashing the Communicator. The BBL-3B also supplies a controlled operating voltage from JBE-2 when performing resistance, current, voltage or RF calibrations.
PAMS RAE-5 6. Service Tools Technical Documentation Dongle/Flash Device FLS-4 (Sales Pack) FLS-4 is a dongle and flash device incorporated into one package, developed specifically for POS use.
PAMS RAE-5 6. Service Tools Technical Documentation Service Cable SCH-12 For use with FLS-4 in flashing.
PAMS RAE-5 6. Service Tools Technical Documentation D9-D9 Cable AXS-4 The D9-D9 Cable AXS-4 is used to connect two 9 pin D connectors. e.g. between PC and FPS-8 flash prommer.
PAMS RAE-5 6. Service Tools Technical Documentation MBUS Cable DAU-9C The MBUS Cable DAU-9C has a phone system connector and D9 female. The DAU9C is MBUS/FBUS interface cable between the phone and PC RS-232 interface. Product Code MBUS Cable DAU-9C: 0730138 View of DAU-9C MBUS Cable DAU-9S The MBUS Cable DAU-9S has a modular connector, and is used between PC and the modular T-adapter.
PAMS RAE-5 6. Service Tools Technical Documentation DC Cable SCB-3 The DC Cable SCB-3 is used to connect the Calibration unit, JBE-1 to the charger connection Vin of the phone when doing the charger calibration service procedure. Product Code DC Cable SCB-3: 0730114 View of SCB-3 Service Cable SCH-8 The Service Cable SCH-8 is used between the phone and FPS-8 and it can used between the phone and modular T-adapter.
PAMS RAE-5 6. Service Tools Technical Documentation Power ACH-6 There are several variants of ACH-6 DC Power sources available: Product Code Name of unit Usage area Material code ACH–6E Europe 0675084 ACH–6U/J U.S.
PAMS RAE-5 6. Service Tools Technical Documentation SW Security Device PKD-1 SW security device is a piece of hardware enabling the use of the service software when connected to the parallel (LPT) port of the PC. Without the dongle present it is not possible to use the service software. Printer or any such device can be connected to the PC through the dongle if needed.
PAMS RAE-5 6. Service Tools Technical Documentation Assembly Jig MJS-78 Assembly jig MJS-78 has been developed for assembly and disassembly of RAE-5.
PAMS RAE-5 Technical Documentation 6. Service Tools Soldering Jig MJS-61 MJS-61 is a soldering jig for UBGA components . Product Code Soldering jig MJS-61 . . . . . . . . . . . . . . . . . .
PAMS RAE-5 6. Service Tools Technical Documentation This page intentionally left blank.