8. Troubleshooting
Page 8 – 77
Issue 1 06/01
NOYES
OK?
Cycle the power, retry
OK?
CSP filters Z401 to Z404
Check, replace
Problem with QWERTY
keypad _2
Connect ROW0 to COL0
Measure the short circuit with oscilloscope
Signal rise and fall times between 80 to 120 ns,
Repeat for each ROW– COL pair.
Switch the power on, wait for reboot
Connect Flex and UI module to the jig.
Push the faulty key, check the column signal.
Signal rise/fall time 120 to 200 ns? (1)
NO
D300 faulty
YES
constant activity?
If no activity or rise/fall times our of range
CSP filters Z401 to Z404
check
OK?
YES
Figure 64.
Table 1. Keyboard matrix (keys on UL2 module highlighted) – English keymat