7. Service Software Instructions
Page 7 – 7
Issue 1 06/01
Installation
Mechanical Connections
Caution: Make sure that you have switched off the PC and the printer
before making connections.
Caution: Do not connect the PKD–1 key to the serial port. You may
damage your PKD–1 !
The software controls RAE–3 via a separate adapter connected to the serial port
of the PC, and to the phone bottom connector (DAU–9C cable).
Attach the dongle PKD–1 to the parallel port 1 (25–pin female D–connector) of the
PC. When connecting PKD–1 to the parallel port, be sure that you insert the com-
puter side of the PKD–1 to the PC (male side). If you use a printer on parallel port
1, install the PKD–1 between the PC and your printer cable.
The PKD–1 should not affect devices working with it. If some errors occur (errors
in printing are possible) please try printing without the PKD–1. If printing is OK with-
out the PKD–1 please contact your dealer. We will offer you a new PKD–1 in ex-
change for your old one.
The program is delivered on a diskette and is copy protected with a dongle PKD–1.
It must be present in parallel port when using Service software.
Installing the software on PC Hard Disk
The program can also be installed on the hard disk, which is recommendable to
obtain a maximum data access rate.
Keep the original diskette safe to enable upgrading of the program !
If you plan to use PCL Start service software, you must install it before installing
Service software, see PCL Start installation instructions.
To install the new Service software program, follow the steps below:
1. insert the new Service software diskette
into drive A: of your computer
2. start Windows, and open File Manager
log into drive a:
type
A:
and press <Enter>
3. start INSTALL.EXE and
type C:
and press <Enter>
install Service software to drive C:
To install product specific DLL’s, take your RAE–3 DLL disks, and repeat the steps
above.