User Guide

PAMS
Technical Documentation
RAE-3
7. Service Software Instructions
Page 7 – 41
Issue 1 06/01
PCN
Spectrum Analyzer Settings
Use an appropriate attenuator 10 or 20dB insertion loss and set the Reference
Level Offset according to insertion loss from the phone to the Spectrum Analyz-
er.
Set the Spectrum Analyzer according to the following settings.
Parameter PCN
Center frequency 1747.8 MHz
Frequency span 300 kHz
Resolution Bandwidth 3 kHz
Video Bandwidth 3 kHz
Sweep time 3 s
Detector type Max. peak
reference level 35 dBm
Marker 1 1747.73229 MHz
Marker 2 1747.8 MHz
Marker 3 1747.86771 MHz
Phone Settings
Connect the phone to the computer and to the Spectrum Analyzer.
Using WinTesla to select the following:
Product
B
and
P
CN
This activates the PCN band. Then select the following:
Te
sting
R
F Controls