7. Service Software Instructions
Page 7 – 23
Issue 1 06/01
RX Filter Calibration (Automatic)
This calibration is calibrating the Baseband filter inside Hagar, for this reason
the calibration is not done in both bands.
Select: T
uning Alt+t
R
X Measurements
A window now pops–up:
Figure 23.
In the ”Select Function” frame select RX ”Filter calibration (Automatic)”. No ex-
ternal signal is needed for this, just click ”Measure”, wait a few seconds and
then click ”Save Defaults”.