User Guide

PAMS
Technical Documentation
RAE-3
6. Service Tools
Page 6 – 8
Issue1 06/01
Detection Switches
There are three switches by which different detections can be done. Switches are
press switch type so the connection is made only while the switch is pressed.
1 S101: Head set detection
2 S102: Hook detection
3 S103: Accessory detection
Starting
Open the cover of the jig and place SIM card and microphone to their places if
needed.
Then place modules of RAE–3 to proper positions: first bl8 / kl8 then in order jc4
(board to board adapter), ul8 (keymat on it if needed) and (keymat under if needed)
dl2 / dl1. Give special attention to connections of board to board connectors, con-
nectors are not specified for continuous removing.
Close the cover of the jig.
Turn the jig over.
Connect the flex to UI module.
Place memory card and/or audio holder under its/their covers.
Connect the necessary cables. Jig is ready for use.
Power ON
There are two working modes in jig:
Default State
Entering to default state does not require any user actions. Just turn the power of
the source ON. EPOC software will not run. There is a notification about the state
in PDA display. Wintesla service software can be used with jig, different kind of test
cases will work (PDA display test, MMC test, etc.).
EPOC Running State
”Run EPOC” switch is needed to be pressed down while turning the power ON. The
switch can be released after the SW has started to boot up. EPOC software will
now run.
In Use
For simulation of cover open / cover closed there is a magnet toggle on cover of
the jig. Sticker beside the toggle describes the meaning of positions. The magnetic
force (field strength) is a bit weaker than in Linda communicator.