PAMS Technical Documentation RAE-3 Series PDA 6. Service Tools Issue1 06/01 Copyright 2001. Nokia Mobile Phones. All Rights Reserved.
PAMS RAE-3 6.
PAMS Technical Documentation RAE-3 6. Service Tools CONTENTS –Troubleshooting Page No Module Jig MJS–14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Views of MJS–14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . User Guide for MJS-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Warnings: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PAMS RAE-3 6. Service Tools Technical Documentation D9-D9 Cable AXS-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of AXS-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MBUS Cable DAU–9C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of DAU–9C . . . .
PAMS RAE-3 6. Service Tools Technical Documentation Module Jig MJS–14 The module jig MJS–4 is used for RAE–3 module testing and repairing. There are slots for each module in the jig. The jig includes connections for charger, power supply, external RF, audios and FBUS/MBUS. Slots for Memory card and SIM card are also included. This equipment is powered by a laboratory source. Product Code Module Jig MJS–14: 0770175 Views of MJS–14 Seen from left Seen from right Seen from front Figure 1.
PAMS RAE-3 6. Service Tools Technical Documentation Seen from back Figure 2. Note: Page 6 – 6 MJS–14, the backside The nominal supply voltage for MJS–14 is +4.0 V. The supply voltage must not exceed +4.1 V.
PAMS RAE-3 Technical Documentation 6. Service Tools User Guide for MJS-14 Warnings: High Voltage There is a 1kV high voltage solder point beside left upper corner of PDA display. Keep the cover always on the dangerous area unless measuring under the PWB. Power Source Do not connect negative voltage to Voltage IN –terminals. Do not connect voltages over 4,2 volts to Voltage IN –terminals. Flash Mode vs.
PAMS RAE-3 6. Service Tools Technical Documentation Detection Switches There are three switches by which different detections can be done. Switches are press switch type so the connection is made only while the switch is pressed. 1 S101: Head set detection 2 S102: Hook detection 3 S103: Accessory detection Starting Open the cover of the jig and place SIM card and microphone to their places if needed.
PAMS RAE-3 6. Service Tools Technical Documentation There are extra GNDs included to jc4 board to board adapter. There is also a special GND pin in middle of the jig. Finishing Before turning the main source off press the nail in audio cover to make an interrupt to processor. This is important especially if you have an active call ON or data transfer going to/from memory card (or serial flash).
PAMS RAE-3 6. Service Tools Technical Documentation Table 1.
PAMS RAE-3 6. Service Tools Technical Documentation Flash Prommer FPS-8 (Sales Pack) The Flash Prommer FPS–8 is used to update the main software of the phone. Updating is done by first loading the new MCU software from the PC to the flash prommer, and then loading the new SW from the prommer to the phone. When updating more than one phone in succession, the MCU software only needs to be loaded to the prommer once.
PAMS RAE-3 6. Service Tools Technical Documentation Calibration Unit JBE-2 Calibration Unit JBE–2 is needed for the resistance, current– and voltage calibrations of a RAE–3 Communicator. These calibrations are needed so that the charging situation would be precise enough. NOTE: The JBE–2 is also the voltage source for the BBL–3B service battery. JBE–2 is the only service equipment which can provide enough current for any service case.
PAMS RAE-3 Technical Documentation 6. Service Tools User Guide for JBE-2 Service Operations Needed equipment: a laboratory source, a calibration unit JBE–2, a service battery BBL–3B and a service cable DAU–9C. Use the JBE–2 calibration unit as a power source for the phone. It is the only service tool which can provide needed currents in any service case. The JBE–2 is powered by a laboratory source. Used voltages are 8,0 volts for normal service and 10,5 volts for energy management calibrations.
PAMS RAE-3 6. Service Tools Technical Documentation Service Car Kit HCL-1 The Service Car Kit, HCL–1 is used for RF tuning of a RAE–3 communicator. HCL–1 is modified from CRM–1 car kit. HCL–1 is used as interface between RAE–3 and service software (Wintesla) while doing RF tuning and power management. Note 1: Other needed accessories for RF tuning are Modular T adapter and DAU–9S.
PAMS RAE-3 6. Service Tools Technical Documentation User Guide for HCL-1 Connection to Service SW A service car kit HCL–1 is used with a Wintesla service software. Needed accessories are Modular–T–adapter and DAU–9S cable. With these accessories the MBUS is connected straight from the phone to the PC and the necessary level transformations are executed.. It is also possible to plug the mod8 connector straight to mod10 socket of FPS–8 prommer and control the phone through it.
PAMS RAE-3 6. Service Tools Technical Documentation Dummy Service Battery BBL-3B The Dummy Service Battery BBL–3B (with banana clips) is used in place of the communicator’s normal battery during service to supply a controlled operating voltage from FPS–8 when flashing the communicator. NOTE: Do not connect BBL–3B straight to a voltage source.
PAMS RAE-3 6. Service Tools Technical Documentation D9-D9 Cable AXS-4 The D9–D9 Cable AXS–4 is used to connect two 9 pin D connectors. e.g. between PC and FPS–8 flash prommer.
PAMS RAE-3 6. Service Tools Technical Documentation MBUS Cable DAU–9C The MBUS Cable DAU–9C has a phone system connector and D9 female. The DAU9C is MBUS/FBUS interface cable between the phone and PC RS–232 interface. Product Code MBUS Cable DAU–9C: 0730138 View of DAU–9C MBUS Cable DAU-9S The MBUS Cable DAU–9S has a modular connector, and is used between PC and the modular T–adapter.
PAMS RAE-3 6. Service Tools Technical Documentation DC Cable SCB–3 The DC Cable SCB–3 is used to connect the Calibration unit, JBE–1 to the charger connection Vin of the phone when doing the charger calibration service procedure. Product Code DC Cable SCB–3: 0730114 View of SCB–3 Service Cable SCH-8 The Service Cable SCH–8 is used between the phone and FPS–8 and it can used between the phone and modular T–adapter.
PAMS RAE-3 6. Service Tools Technical Documentation Power ACH-6 There are several variants of ACH–6 DC Power sources available: Product Code Name of unit Usage area Material code ACH–6E Europe 0675084 ACH–6U/J U.S.
PAMS RAE-3 6. Service Tools Technical Documentation SW Security Device PKD-1 SW security device is a piece of hardware enabling the use of the service software when connected to the parallel (LPT) port of the PC. Without the dongle present it is not possible to use the service software. Printer or any such device can be connected to the PC through the dongle if needed.
PAMS RAE-3 6. Service Tools Technical Documentation This page intentionally left blank.