PAMS Technical Documentation RAE–2 Series Chapter 8 Service Tools Original, 02/99 Copyright 1999. Nokia Mobile Phones. All Rights Reserved.
PAMS RAE–2 Service Tools Technical Documentation AMENDMENT RECORD SHEET Amendment Number Date 02/99 Page 8 – 2 Inserted By Comments Original Original, 02/99
PAMS Technical Documentation RAE–2 Service Tools CONTENTS -Service Tools Page No Service Battery BBS-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of BBS-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Module Jig MJS-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PAMS RAE–2 Service Tools Technical Documentation View of DAU-9S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MBUS Cable DAU-9C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of DAU-9C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D9-D9 Cable AXS-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . .
PAMS RAE–2 Service Tools Technical Documentation Service Battery BBS-5 The service battery BBS-5 is used in place of the normal battery of the communicator during service to supply a controlled operating voltage from JBE-1, JBP-8 or FLA-7. NOTE: DO NOT connect BBS-5 straight to a voltage source . The service battery is also required when flashing the phone.
PAMS RAE–2 Service Tools Technical Documentation Module Jig MJS-4 The module jig MJS-4 is used for RAE-2 module testing and repairing. There are slots for each module in the jig. The jig includes connections for charger, power supply, external RF, audios and FBUS/MBUS. Slots for Memory card and SIM card are also included. This equipment is powered by a laboratory source. Product Code Module Jig MJS-4: 0770116 View of MJS-4 Note: Page 8 – 6 The nominal supply voltage for MJS-4 is +4.0 V.
PAMS RAE–2 Service Tools Technical Documentation Flash Loading Adapter FLA-7 The flash loading adapter FLA-7 is used with the service battery BBS-5 and service cable SCH-8. Power is supplied to the FLA-7 from the ACL-3 charger. Power for the FPS-4 can be connected via the FLA-7 by SCF-7 DC power cable. The adapter is connected to the flash prommer FPS-4S by the AXS-5 cable and to the security box TDF-4 by the XCM-1 cable.
PAMS RAE–2 Service Tools Technical Documentation Calibration Unit JBE-1 The calibration unit JBE-1 is used for power management calibrations of a RAE-2 communicator. The calibration unit is also a voltage source for the service battery BBS-5. This equipment is powered by a laboratory source. Product Code Calibration Unit JBE-1: 0770118 View of JBE-1 Note: The nominal supply voltages for JBE-1 are +7,0 V for normal service activities and 10,5 V for calibrations.
PAMS RAE–2 Service Tools Technical Documentation Power Junction Unit JBP-8 The power junction unit JBP-8 is used to provide power for eight BBS-5 service batteries at the same time. This is how eight PDA memories of RAE-2 phone can be updated at the same time. This equipment is powered by a laboratory source. Product Code Power Junction Unit JBP-8 0770141 View of JBP-8 Note: Original, 02/99 The nominal supply voltage for JBP-8 is +4,0 V. The supply voltage must not exceed +4.1 V.
PAMS RAE–2 Service Tools Technical Documentation Service Car Kit HCR-2 The service car kit HCR-2 is modified from CRH-2 car kit of RAE-2 phone.
PAMS RAE–2 Service Tools Technical Documentation Flash Prommer FPS-4S (Sales Pack) The flash prommer FPS-4S is used to update the main software of the phone. Updating is done by first loading the new MCU software from the PC to the flash prommer, and then loading the new SW from the prommer to the phone. When updating more than one phone in succession, the MCU software only needs to be loaded to the prommer once.
PAMS RAE–2 Service Tools Technical Documentation Security Box TDF-4 The security box TDF-4 is required for updating MCU software, and infra red testing.
PAMS RAE–2 Service Tools Technical Documentation Service Cable SCH-8 The service cable SCH-8 is used between the phone and the modular T-adapter or between the phone and the flash loading adapter FLA-7.
PAMS RAE–2 Service Tools Technical Documentation DC Power Cable SCF-7 The DC power cable SCF-7 is used for connecting power from ACL-3 charger via FLA-7 to FPS-4.
PAMS RAE–2 Service Tools Technical Documentation D15-D15 Cable AXS-5 The D15-D15 cable AXS-5 is used to connect two 15 pin D connectors. e.g. between FLA-7 and FPS-4S.
PAMS RAE–2 Service Tools Technical Documentation JTAG Cable DKS-6 The JTAG cable DKS-6 is used for connecting the JTAG tap pod to a service battery BBS-5.
PAMS RAE–2 Service Tools Technical Documentation DC Cable SCB-3 The DC cable SCB-3 is used to connect the calibration unit JBE-1 to the charger connection Vin of the RAE-2 phone when doing the charger calibration service procedure.
PAMS RAE–2 Service Tools Technical Documentation MBUS Cable DAU-9S The MBUS cable DAU-9S has a modular connector, and is used with the service car kit HCR-2 and the module jig MJS-4 with a modular T-adapter.
PAMS RAE–2 Service Tools Technical Documentation MBUS Cable DAU-9C The MBUS cable DAU-9C has a RAE-2 phone system connector, and is used between the phone and external devices (laptops, PCs).
PAMS RAE–2 Service Tools Technical Documentation D9-D9 Cable AXS-4 The D9-D9 cable AXS-4 is used to connect two 9 pin D connectors. e.g. between PC and TDF-4 security box.
PAMS RAE–2 Service Tools Technical Documentation Modular T-adapter The modular T-adapter is a suitable branching unit to provide the needed parallel modular connections.
PAMS RAE–2 Service Tools Technical Documentation SW Security Device PKD-1 SW security device is a piece of hardware enabling the use of the service software when connected to the parallel (LPT) port of the PC. Without the dongle present it is not possible to use the service software. Printer or any such device can be connected to the PC through the dongle if needed.
PAMS RAE–2 Service Tools Technical Documentation Protection Key PKD-4F This protection key is needed for the delivery of the PDA flash voltage. Without it the PDA flash circuits do not receive a programming voltage and the update fails. The PKD-4F is connected to the JTAG connector of the BBS-5 service battery.
PAMS RAE–2 Service Tools Technical Documentation This page intentionally left blank.1.