PAMS Technical Documentation NSE–6 Series Transceivers Service Tools Original 08/98
NSE–6 Service Tools PAMS Technical Documentation CONTENTS Page No Service Box JBU–5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of JBU–5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PNS–5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . .
NSE–6 PAMS Technical Documentation Service Tools Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of DAU–9S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Cable PCS–1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of PCS–1 . . . . . . . . . . . . . . . .
NSE–6 PAMS Technical Documentation Service Tools Service Box JBU–5 The Service Box JBU–5 is used for power supply and current calibration. Also flash loading and functional tests.
NSE–6 PAMS Technical Documentation Service Tools Module Jig MJS–6 The Module Jig MJS–6 is used for repair of system/RF module. * Product Code Module Jig MJS–6: 0770121 View of MJS–6 *Note: Original 08/98 The nominal supply voltage for MJS–6 is +3.6 V. The supply voltage must not exceed +5.0 V.
NSE–6 PAMS Service Tools Technical Documentation Battery Adapter BDS–6 The Battery Adapter BDS–6 is used along with an external battery capacity meter to check battery capacity. Note that Li–ion batteries have an internal protection circuit to prevent deep discharge.
NSE–6 PAMS Technical Documentation Service Tools Flash Loading Adapter FLA–5 (Sales Pack) The Flash Loading Adapter FLA–5 is used with the Service Battery BBD–3 and Service Cable SCH–5. Power is supplied to FLA–5 from the Flash Security Box TDF–4 via the DC cable PCC–1, (The PCC–1 cable can be replaced with a Travel Charger ACH–6), and is connected to the Flash Prommer FPS–4S with the cable AXS–5.
NSE–6 PAMS Service Tools Technical Documentation Flash Prommer FPS–4S (Sales Pack) The Flash Prommer FPS–4S is used to update the main software of the phone. Updating is done by first loading the new MCU software from the PC to the flash prommer, and then loading the new SW from the prommer to the phone. When updating more than one phone in succession, the MCU software only needs to be loaded to the prommer once.
NSE–6 PAMS Technical Documentation Service Tools Security Box TDF–4 The Security Box TDF–4 is required for updating MCU software, and infra red testing. Note 1: TDF–4 is delivered in de–activated mode.
NSE–6 PAMS Service Tools Technical Documentation Service Audio Box JBA–4 The Service Audio Box JBA–4 is used between the Service Cable SCH–5, MBUS Cable DAU–9S, and Audio Cable ADS–1.
NSE–6 PAMS Technical Documentation Service Tools Audio Cable ADS–1 Audio cable is an adapter routing AF signals (MIC/EAR) from 8 pin modular connector to two BNC connectors. It is used to connect JBA–4, SCH–5, and DAU–9S.
NSE–6 PAMS Service Tools Technical Documentation D15–D15 Cable AXS–5 The D15–D15 Cable AXS–5 is used to connect two 15 pin D connectors. e.g. between FLA–5 and FPS–4S.
NSE–6 PAMS Technical Documentation Service Tools DC Charging Cable PCC–1 The DC Cable PCC–1 is used e.g. to connect FLA–5 and TDF–4.
NSE–6 PAMS Technical Documentation Service Tools DC Cable SCB–3 The DC Cable SCB–3 is used to connect the Service Battery to the charger connection Vin of the phone when doing the charger calibration service procedure.
NSE–6 PAMS Technical Documentation Service Tools MBUS Cable DAU–9S The MBUS Cable DAU–9S has a modular connector, and is used with the service Audio Box JBA–4, or a modular T–adapter.
NSE–6 PAMS Service Tools Technical Documentation Power Cable PCS–1 The Power Cable PCS–1 is used to connect the module jigs JBT–1 and JBS–19 to an external power supply. Can be used with FPS–4 also.
NSE–6 PAMS Technical Documentation Service Tools Audio Cable SCA–5 Audio cable is an adapter routing AF signals (MIC/EAR) from phones headset connector to the service box JBU–5.
NSE–6 PAMS Service Tools Technical Documentation Service Cable XCM–5 XCM–5 is a modular cable for flashing.
NSE–6 PAMS Technical Documentation Service Tools Modular T–adapter The modular T–adapter is a suitable branching unit to provide the needed parallel modular connections.
NSE–6 PAMS Service Tools Technical Documentation SW Security Device PKD–1 SW security device is a piece of hardware enabling the use of the service software when connected to the parallel (LPT) port of the PC. Whitout the dongle present it is not possible to use the service software. Printer or any such device can be connected to the PC through the dongle if needed.