User Guide

PAMS
Technical Documentation
NSE–6
Tuning Instructions
Page 9
Original 08/98
2. I/Q Modulator Amplitude Balance and Phase Shift Tuning
The purpose of this tuning operation is to adjust the I/Q modulator d.c. off-
sets and the I/Q modulator amplitude balance and phase shift.
I/Q modulator d.c. offsets, amplitude balance and phase shift tuning:
Select
Tuning –> TX I/Q...
Select I/Q tuning values from PC’s memory, phone’s EEPROM or fac-
tory default values.
Connect spectrum analyzer (with attenuator if needed) to service jig
antenna connector.
Check that TX power level is level 10, channel is 60 and TX data type
is 1.
Adjust spectrum analyzer centre frequency to 902 MHz, Span 200
kHz, Res BW 10 kHz, Video BW 1 kHz and Sweep time 0.5 s.
–67.71 kHz +67.71 kHz
CHF
> 30 dB
> 35 dB
Set this value
to minimum
Amplitude &
phase difference:
Set this value
to minimum
D.C. offset
tunings:
Select the ”TX I d.c. offset” option.
Adjust the level of centre frequency (CHF signal) to minimum by vary-
ing D/A converter value with
<–
and
–>
buttons.
The amplitude difference between CHF–67.7 kHz and CHF should be
>30 dB.
Select option ”TX Q d.c. offset”.
Adjust the level of signal CHF to minimum by varying D/A converter
value with
<–
and
–>
keys.