User Guide

PAMS
Technical Documentation
NSE/M–1/3/6
Service Software Instructions
Page 32
Original 08/98
+/– buttons (+/– and left/right cursor keys):
+ and – buttons will cause power changing by 0.25dB steps. When these
keys are used the coefficient value is updated on the tuning window.
Save button (ENTER):
Dialog is closed and tuned values are
saved
to phone.
Cancel button (ESC):
Dialog is closed and tuning
is not saved
to phone.
When selections are used, the power value checking is made and if it is
not succeeded, error message is shown. The test checks that all power
coefficients are in descending order (same order than power levels).
If the power tuning function is ended and EEPROM values are not re-
ceived or EEPROM fault is noticed, an error message is shown.
When all power coefficients have such values that they don’t cause any
error messages, save can be made. The last used tuning power is in use
after exit.
The next automatic selection is made when this tuning function is ended:
Operation Mode = RX pulsed
TX Power Side Channel Tuning
This feature is available only for NSM–1 phones.
If user has PKD–1 dongle, then tuning is started automatically with EE-
PROM values. With other dongles the Start Tuning dialog is opened, see
Tx Power... command.
With the TX Power Side Channel Tuning dialog user can tune lower
and higher side of band.
NOTE: This is a screen sample, actual values may differ.