PAMS Technical Documentation NSM–3/3D Series Transceivers Service Software Instructions Issue 4 02/2002 Nokia Mobile Phones Ltd.
NSM–3/3D Service Software Instructions PAMS Technical Documentation CONTENTS Service Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hardware requirements for Windows 3.11 . . . . . . . . . . . Hardware requirements for Windows 95/98/NT . . . . . . Software Environment of the Support Modules . . . . . . . . . Service software . . . . . . . . . . . . . . . . . . . . . .
PAMS Technical Documentation NSM–3/3D Service Software Instructions New command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Open... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Initialise... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Normal Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Local Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Band... command . . . . . . . . .
NSM–3/3D Service Software Instructions PAMS Technical Documentation Service Software General To run the Service Software, a parallel port software protection device (PKD–1) has to be connected. TDF–4 box must connected to PC for flashing purposes. The test functions send test messages from PC to mobile stations (MS) and receive results and show them in the PC display. The messages can be sent via M2BUS or FBUS. Note: if this software is to be run on laptops, the power saving feature MUST be switched off.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Service software NSM–3 and 3D specific: Service SW diskette 3.5” for NSM–3 (3D) 0774080 Flash SW packages on CD for NSM–3 0775223 Flash SW packages on CD for NSM–3D 0775280 Issue 4 02/2002 Nokia Mobile Phones Ltd.
NSM–3/3D Service Software Instructions PAMS Technical Documentation This page intentionally left blank. Page 6 Nokia Mobile Phones Ltd.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Installation Mechanical Connections Caution: Make sure that you have switched off the PC and the printer before making connections. Caution: Do not connect the PKD–1 key to the serial port. You may damage your PKD–1 ! The software controls the phone via a separate adapter connected to the serial port of the PC, and to the telephone’s M2BUS (DAU–9S). Attach the dongle PKD–1 to the parallel port 1 (25–pin female D–connector) of the PC.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Installing the Service Software on PC Hard Disk The program is delivered on a diskette and is copy protected with a dongle PKD–1. It must be present in parallel port when using Service software. The program must be installed on the hard disk before use.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Start installation, double–click the dk2wn32.exe file. Follow the instructions on the screen. When installation is completed remove the dongle driver software disk from your floppy drive. Continue with the support modules installation.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Common Properties of the User Interface This chapter describes how the User Interface CLF (Common Look and Feel) must appear to the user. The User Interface MUST be capable of being driven without the use of a mouse, as the service engineer rarely has space on the bench to use a mouse.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Cancel button (ESC) The Dialog box is closed and application is started, but the Faultlog feature is disabled. Help button (F1) Activates the Windows Help application and displays context sensitive Help. Main Window Title bar The title bar is located at the top of the window.
NSM–3/3D Service Software Instructions PAMS Technical Documentation The status bar texts are explained in detailed in each of command’s description. The right areas of the status bar indicate which of the following keys are latched down: Indicator Description USER Entered Login ID. CAP The Caps Lock key is latched down. NUM The Num Lock key is latched down. SCRL The Scroll Lock key is latched down. Tool bar The tool bar is NOT defined and will not be implemented until specified by this document.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Menu Bar The Service Software package will have two menu bar configurations. The first, is an abbreviated version that contains the minimum number of menus that allows package configurations when a phone is NOT connected.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Configure The Configure menu contains at least the following items: • Options... • Directories... • Faultlog... • Phone Type Specific configuration items (where applicable) Tuning The Tuning menu contains at least the following menu sections: • RX Filter Calibration... • RX Calibration... • AM Suppression... • Tx Power... • Tx I/Q... • Energy Management Calibration...
PAMS Technical Documentation NSM–3/3D Service Software Instructions Software The Software menu contains at least the following menu sections: • Product Profile... • Start Up Self–tests... • Set Factory Values • Phone Identity... • Warranty State... • Production Data Edit... Dealer The Dealer menu contains at least the following menu sections: • User Settings... • Short Code Memory... • SCM & User settings ... • Restore User Defaults... • Set UI/DEV Default Values ... • Operators Settings... • IWR Swap...
NSM–3/3D Service Software Instructions PAMS Technical Documentation Phone Identity Window The Phone Identity window should contain, as a minimum, the following data: • Software Version(s) • Hardware Version(s) • Serial Number(s) • Product Code This window will only be used as a display window and therefore will not allow editing of the displayed data. This window will not contain any controls other than a scroll bar.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Mouse Cursors The standards Windows pointer will be used as the mouse cursor. During time consuming tasks e.g. communication to phone, an hour glass will be shown informing the user that a task is in progress. The application uses the hour glass cursor to inform user that the application has taken the control and any actions from user will be ignored.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Shift Hot Keys Key by Description Defined Shift+F5 Local Mode NMP Key by Description Defined Alt+P Product Menu NMP Alt+P,N New NMP Alt+P,O Open NMP Alt+P,C Close NMP Alt+P,I Initialize Pop–up NMP Alt+P,I,N Normal Mode NMP Alt+P,I,L Local Mode NMP Alt+P,F Faultlog Pop–up NMP Alt+P,F,A Activate Faultlog NMP Alt+P,F,E Edit Faultlog NMP Alt+P,X Exit Application NMP Alt+C Configure NMP Alt+C,O Opt
PAMS Technical Documentation NSM–3/3D Service Software Instructions Alt+E,U,I Audio Internal NMP Alt+E,U,E Audio External NMP Alt+E,U User Interface NMP Alt+E,C Call Simulation NMP Alt+E,N Noise Sensitivity NMP Alt+E,I IR Test NMP Alt+S Software Menu NMP Alt+S,P Product Profile NMP Alt+S,S Start–up Self Tests NMP Alt+S,V Set Default Values NMP Alt+S,I Phone Identity NMP Alt+S,P Production Data Edit NMP Alt+S,F Flash Phone NMP Alt+D Dealer Menu NMP Alt+D,U User Se
NSM–3/3D Service Software Instructions PAMS Technical Documentation Help Functions The Help User Interface will be the standard Windows help tool called WinHelp. The context sensitive help is activated with F1–key. Help contains also Using Help which describes how to use help facility. Refer to the Windows manual for detailed description on the Windows Help. Dialog boxes The Service Software application uses many different dialog boxes. Dialog boxes are used to display data and prompt the user for input.
PAMS Technical Documentation NSM–3/3D Service Software Instructions The dialog box will also contain a Yes button, a No button, and a Help button. Yes button (Alt+Y or Y) (default key): Accepts confirmation or question. No button (Alt+N or N): Denies confirmation or question. Help button (Alt+H): Opens context sensitive help as F1–key does. The buttons may also be OK and Cancel. The operation of these buttons are the same as in the Note dialog box.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Custom Dialog boxes All custom dialog boxes will contain the predefined buttons as defined below in the section – Buttons. However, it is recognized that features may require additional button types, but the addition of these non–standard buttons should be carefully considered to minimize any inconsistencies between implementations. The buttons will be positioned down the right–hand side of the dialog boxes.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Replies Yes to a question asked of the user. No button (ALT+N or N): Replies No to a question asked of the user. Help button (ALT+H): Opens context sensitive help as F1–key does. Reporting Status The status bar will be used to report the present status to the user. When a feature is initiated, the status bar will be updated with a brief description of the function.
NSM–3/3D Service Software Instructions PAMS Technical Documentation NSM–3 and 3D Features Menu bar After Sales SW’s menus follow the menu structure specified in WinTesla User Interface Specification. This specification describes the functionality that differs from the WinTesla specification.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Normal Mode Activation Status Bar Text Alt, P, I, N Initialises phone to normal mode F5 When normal mode has been activated or program has been started, self–test results will be asked from MCU. If fault was found in the tests, an error message is shown. If normal mode has been set successfully (no self test error has been found), and paging listening has been started, the used AFC value is requested from MS.
NSM–3/3D Service Software Instructions PAMS Technical Documentation GSM Activation Alt, P, B, G Status Bar Text Set phone to GSM band. PCN Page 26 Activation Status Bar Text Alt, P, B, P Set phone to PCN (GSM1800) band. Nokia Mobile Phones Ltd.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Tuning The tuning menu offers functions for ME adjustments. RX Filter Calibration... command Activation Status Bar Text Alt, T, M Open RX Measurements dialog box Starts RX Filter Calibration tuning for the phone. Dialog mode: Modal RX Measurements dialog includes the following items: Select Function listbox: Shows list of automatic selections. When selection is made values are loaded from phone.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Save button: This saves values to the phone. Close button: This button closes the dialog without saving anything. Help button: This button opens Help. Page 28 Nokia Mobile Phones Ltd.
PAMS Technical Documentation NSM–3/3D Service Software Instructions RX Calibration... command Activation Status Bar Text Alt, T, R Open RX Calibration dialog box Starts RX calibration. Next automatic selections are made when this tuning function is activated: • Phone is set to local mode • Update RF information window The measurement is started automatically when RX calibration is entered. The measurement is done in five steps: 1.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Dialog mode: modal RX Calibration dialog includes the following items: AFC information box: Shows AFC init value, AFC slope and PSW slope values. AGC List box (ALT+A): AGC, DAC, Voltage. Repeat button (ALT+R): Measurement can be started again by pressing this button. Save button (ALT+S): Dialog is closed and tuning is saved to phone. Cancel button (ESC): Dialog is closed and tuning is not saved to phone.
PAMS Technical Documentation NSM–3/3D Service Software Instructions RX AM Suppression... command Activation Status Bar Text Alt, T, M, A Open RX Measurements dialog box Starts RX AM Suppression tuning for the phone. Dialog mode: Modal RX Measurements dialog includes the following items: Select Function listbox: Shows the list of automatic selections. When a selection is made the values are loaded from the phone. Value group: This group includes several items.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Save button: This saves the values to the phone. NOTE: After GSM Suppression the same tuning must be made for the PCN band also! To change the band go to Product Menu and select Band, PCN. Close button: This button closes the dialog without saving anything. Help button: This button opens Help. Page 32 Nokia Mobile Phones Ltd.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Tx Power... command Activation Status Bar Text Alt, T, X Open TX Power Tuning dialog box Starts TX power tuning. When the user has PKD–1 dongle in place tuning is started automatically with EEPROM values. Tuning values are loaded from program’s internal memory.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Dialog mode: modal TX Power Tuning dialog includes following items: Level, Coefficient and Targets list box (ALT+L): The power is presented in GSM or PCN values. The base power is selected automatically when the dialog is opened. The test value is not saved to the EEPROM. The test value can be changed during tuning as other power coefficients and the program remembers its value when tuning function is activated later again.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Base offset edit box: This edit box shows the base offset value that the user can change. The base level calculation check box must be checked before this value is used. After this value is changed the user must do the calculation. NOTE: Do not use Enter button to accept this value. +/– buttons (+/– and left/right cursor keys): + and – buttons will cause power changing by 0.25dB steps.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Tx I/Q... command Activation Status Bar Text Alt, T,Q Open TX I/Q Tuning dialog box This function is used for tuning TX I and Q branch DC offset, amplitude difference and phase difference. If the the user has a PKD–1 dongle and other than NSM–X phone, then tuning is started automatically with EEPROM values. When using other dongles this selection opens same Start Tuning dialog as with TX Power Tuning.
PAMS Technical Documentation NSM–3/3D Service Software Instructions value range is –100%...100%. The value is rounded to the nearest integer value. Tune Amplitude Difference scroll bar (ALT+A): When this selection is made the user can increase or decrease the amplitude difference within 0.1 dB steps. The value range is –1...1. Tune Phase Difference scroll bar (ALT+P): When this selection is made the user can increase or decrease the phase difference within 0.5° steps.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Energy Management Calibration... command Activation Status Bar Text Alt, T,E Calibrate Battery Voltage This function is for battery a/d and charge current tunings. NOTE: This Calibration must be done when N100, N101 or a discrete component affecting these two is changed. Before battery a/d tuning is started a voltage setting request is shown to the user (Set supply voltage to 10,5 V). Service Battery is in this case JBU–6.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Energy Management Calibration dialog includes following items: Settings group box: Contains EM calibration setting check boxes: 1. Run battery & charger default values checkbox (ALT+1): Runs battery & charger default values to phone when selected 2. Battery voltage checkbox (ALT+2): Calibrates battery voltage A/D value. 3. Charger voltage checkbox (ALT+3): Calibrates charge voltage A/D value. 4.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Testing The Testing sub menu offers functions for ME testing. RF Controls... command Activation Status Bar Text Alt, E,R Open RF Controls dialog box This function is used for RF testing. Command opens RF Controls dialog, which contains data for testing and adjustments.
PAMS Technical Documentation NSM–3/3D Service Software Instructions When TX is selected, the next functions are made: Data transmission is activated If operation mode is continuous, – Operation mode is set to burst RF Information window is updated Continuous mode radio button is disabled. Note! Function is activated immediately, Apply is not needed.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Channel edit box (ALT+H): The user can enter here a channel number that is used for both transmission and receiving. The frequency of the selected channel is shown after selection. Monitoring Channel edit box (ALT+M): This field selects an adjacent monitoring channel. The frequency of the selected channel is shown after selection.
PAMS Technical Documentation NSM–3/3D Service Software Instructions OPERATION MODE = BURST: TX Power Level: Updated Continuous Mode Channel: Greyed Channel: Updated OPERATION MODE = CONT.
NSM–3/3D Service Software Instructions PAMS Technical Documentation RSSI Reading... command Activation Status Bar Text Alt, E,R Read continuously RSSI value Command opens RSSI Reading dialog: Dialog mode: modal RSSI value is read continuously until the user presses ESC–key or Close button to cancel reading. RSSI Reading dialog includes following items: Close (ENTER) button: Closes the RSSI Reading dialog. Does not send anything to phone. Help button: Context sensitive help.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Self Tests... command Activation Status Bar Text Alt, E,S Open MCU Self–tests dialog box Command is used for reading self test results and running self tests. When the selection is made, the test result is read from ME. The test result will be shown to the the user within MCU Self–test dialog.
NSM–3/3D Service Software Instructions PAMS Technical Documentation message in a few seconds, the the user is informed by special info window, where the user is asked to turn the power on and then press the return key. Note also that power–off test (if passed) turns power off and power should be reconnected by using the phones keypad after the successful test.
PAMS Technical Documentation NSM–3/3D Service Software Instructions H COBBA Parallel..................... I EEPROM Sec Checksum................ J PPM Validity.................... K Warranty State.................... L SW Version.................... Issue 4 02/2002 Nokia Mobile Phones Ltd.
NSM–3/3D Service Software Instructions PAMS Technical Documentation ADC Readings... command Activation Status Bar Text Alt, E,A Open ADC Readings dialog box. Command is used to read and show A/D values from phone. Command opens ADC Readings dialog. Dialog mode: modal ADC Readings dialog has static text field where measurements are updated to window every one second. ADC Readings dialog includes following items: Close (ENTER) button: Closes the ADC Readings dialog. Does not send anything to phone.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Audio... command Activation Status Bar Text Alt, E,U Opens a submenu which contains following options: Internal Audio Loops Activation Status Bar Text Alt, E,U,I Open Internal Audio loops dialog box. Command is used for making internal audio loop tests in Internal Audio Loops dialog.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Turns buzzer off. Internal Audio Loop group: Input group: Next two different values can be selected for input: Internal radio button (ALT+I): Turns internal input. External radio button (ALT+I): Turns external input. Headset radio button (ALT+A): Turns headset input. Note: If Output is not Headset, loop is turned off. Output group: Next two different values can be selected for output: Internal radio button (ALT+T): Turns internal output.
PAMS Technical Documentation NSM–3/3D Service Software Instructions User Interface... command Activation Status Bar Text Alt, E,U Open User Interface Tests dialog box Command is used for making display tests in the Display Tests dialog. Dialog mode: modal Display Tests dialog includes following items: 1. Test Pattern radio button (ALT+1): In test display 1 all indicators are displayed and the display is filled with chessboard pattern. 2.
NSM–3/3D Service Software Instructions PAMS Technical Documentation IR Test... command Activation Status Bar Text Alt, E,I IR module test Command is used for making IR module test. Function opens the IR Test dialog: Dialog mode: modal IR Test dialog includes following items: Result box: Result can be OK/FAILED Test (ENTER) button: Starts the IR Test. Close button: Closes the IR Test dialog. Page 52 Nokia Mobile Phones Ltd.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Sleep mode... command Activation Status Bar Text Alt, Open dialog box Command is used to put the phone in Sleep mode for a certain period of time. Function opens the Sleep Mode Test dialog. Dialog mode: modal Sleep mode Test dialog includes the following items: Sleep time box: Edit box where you can enter a value in ms. Test (ENTER) button: Starts Sleep mode Test. Close button: Closes the Sleep mode Test dialog.
NSM–3/3D Service Software Instructions PAMS Technical Documentation This page intentionally left blank. Page 54 Nokia Mobile Phones Ltd.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Vibra Test... command Activation Status Bar Text Alt, E, V Vibrator module test This command is used for testing phone’s or battery’s vibrator. Function opens Vibra Test dialog: Dialog mode: modal Vibra Test dialog includes following items: Vibra Value box: Edit box where you can enter value from 0 to 255. Test (ENTER) button: Starts Vibra Test. Close button: Closes the Vibra Test dialog.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Software Product Profile... command Activation Status Bar Text Alt, S,P Open Product Profile settings dialog box. Function is used for making product profile settings. When the command is activated the product profile information is read from EEPROM and Product Profile dialog is opened. Dialog mode: modal Product Profile dialog includes the following items: Settings list box (ALT+E): A list where the user can select desired setting.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Start Up Self–tests... command Activation Status Bar Text Alt, S,S Open MCU start Up self–tests dialog box. Function is used for changing the state of the EEPROM selectable tests in MCU Start Up Self–tests dialog. Dialog mode: modal MCU Start Up Self–tests dialog includes following items: Tests list box (ALT+T): When the dialog is opened, the previous values will be read from the MCU EEPROM and shown on the list box.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Set Factory Values... command Activation Status Bar Text Alt, S,V Set factory values With this selection the user can set factory defaults to the phone. This selection opens the Default Factory values dialog. Dialog mode: modal Default Factory Values dialog includes the following items: Settings list box: Contains the selectable factory values. Set button: Sets the selected factory value to phone.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Phone Identity... command Activation Status Bar Text Alt, S,I Open Phone Identity dialog box for editing Function is used to edit phone identity. NOTE: product code cannot be changed with this dialog, if product code is invalid, e.g. after EEPROM change, change product code first with Production Data Edit.
NSM–3/3D Service Software Instructions PAMS Technical Documentation User Name edit box (ALT+U): Field where the user can enter user identification. IMEI edit box (ALT+I): Field where the user can enter an IMEI value. Field can contain up to 40 digits. This field is automatically filled, if ME is connected to the PC when dialog is loaded. Product Code edit box (ALT+P): Field where the user can enter Product Code value. This field is automatically filled, if ME is connected to the PC when dialog is loaded.
PAMS Technical Documentation NSM–3/3D Service Software Instructions SIM Lock programming data is read from file or entered by the user to this field. Input entries for FAX check box (ALT+F): When checked all fields become editable to allow the user to enter values by hand e.g. from FAX. Close button (ESC): Cancels all edits and does not save values to phone. Help button Opens a help text. Write button (ALT+W): Writes programming data to phone. Actions are selected with Action Selection radio button.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Warranty State... command Activation Status Bar Text Alt, S,W Open Warranty State dialog box This command is used to set the warranty state of a phone. When selected the application opens the Warranty State dialog box. Dialog mode: modal Warranty State dialog includes the following items: State static text: USE For normal phones. DEFECTIVE For phones which are being swapped.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Production Data Edit... command Activation Status Bar Text Alt, S,P Open Production Data Edit dialog box This command is used for programming HW version and other production data to phone. Only fields that are editable are validated and written to the phone. The function opens the following Production Data Edit dialog box.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Dealer The dealer sub menu offers functions for ME settings for dealers. User Settings... command Activation Status Bar Text Alt, D,U Open User Setting dialog box This command is used to edit some user settings. When this command is selected the user is asked to read settings from the phone. After answering that dialog following User Settings and Values dialog is displayed. NOTE: This is a screen shot example.
PAMS Technical Documentation NSM–3/3D Service Software Instructions The user can load user settings from file. Edit... button (ALT+D): Start Windows Paintbrush to edit a loaded or saved graphical Wake up message. This picture is not available, if the phone does not support WUG. OK button (ENTER): Writes the user settings to phone. Cancel button (ESC): Closes the dialog box Short Code Memory... command Activation Status Bar Text Alt, S,C Open Edit SCM dialog box.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Edit the Name. Number edit box (ALT+N): Edit the Number. Group edit box: Edit the Group number. SCM list box (ALT+C): List for available names and numbers. Write MS / Write SIM button (ALT+W): Write SCM values to phone or SIM and checks the validity of names and numbers. Read MS / Read SIM button (ALT+R): Read SCM values from phone or SIM. Save File...
PAMS Technical Documentation NSM–3/3D Service Software Instructions SCM & User Settings... command Activation Status Bar Text Alt, D,M Open SCM & User settings dialog box. This command is used to get SCM and user settings from phone to file and vice versa. Following information is loaded/saved with this dialog: all user settings, graphical/text wake up message, SCM, alarms, calendar items and CLI logos and groups. Only values of supported features are saved or loaded.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Restore User Defaults... command Activation Status Bar Text Alt, D,R Open Restore Default User Settings. This command is used to restore Default User Settings, if they have degenerated. Dialog may be opened from menu, or is opened automatically, when loading or saving user settings fails or is skipped during flashing (see Flash Phone... command). The dialog is also opened after full factory set.
PAMS Technical Documentation NSM–3/3D Service Software Instructions enabled according to settings available in selected Market Area. Graphical Welcome Message check box (ALT+G): When checked the user selects to restore default graphical welcome message. CLI Logos check box (ALT+C): When checked the user selects to restore default CLI logos. Product Profiles check box (ALT+P): When checked the user selects to restore default product profiles.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Operators Settings... command Activation Status Bar Text Alt, D,O Open Operator Settings dialog. This command is used to set operator settings This selection opens the following Operator Settings dialog. Dialog mode: modal Operator Settings dialog box includes the following items: Settings group: Country Code edit box (ALT+C): The user can edit country code (3 or 4 digits).
PAMS Technical Documentation NSM–3/3D Service Software Instructions IWR Swap... command Activation Status Bar Text Alt, D,I Open IWR Swap dialog. This command is used to swap serial numbers of two phones. This selection opens following IWR Swap dialog.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Flash Phone... command Activation Status Bar Text Alt, D,F Open Flash Phone dialog box. This command is used for flashing new software into the phone. When flashing dead phone, the user may be asked to select phone type. If more than one phone is flashed without closing the dialog, then the user must press Check button after the phone has been replaced. Selection opens the following Flash Phone dialog box.
PAMS Technical Documentation NSM–3/3D Service Software Instructions NOTE: This is a screen sample for NSM–3D, actual information may differ. Dialog mode: modal Flash Phone dialog box includes following items: Market Area group: Drop down list box (ALT+M): The user can select correct market area for phone. With this selection correct image and PPM files are loaded to edit fields. Usually this is the correct way to select files to be flashed.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Displays path of PPM package file to be flashed. … button: Opens Open File dialog, with which the user can select a PPM package file to be flashed to ME. If the user selects OK button, the name of selected file is copied to PPM Image edit field. Usually you should use Market Area list box to select PPM file. Version in File edit field (read only): MCU SW version string of the PPM package.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Forces downloading of selected PPM file to a prommer even, if it already exists there. Can be used to replace a corrupted file in a prommer with a proper one. ROM Version Group: ROM Version edit box: Shows rom version of flashed phone. Check button (Alt+A): Checks connected phone, reads MCU SW and ROM version from the phone and loads market areas. If application cannot detect ROM version, the user is shown ROM Version selection dialog.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Cancel button (ESC): Phone type selection is cancelled and operation is aborted. ROM Version dialog NOTE: This is a screen sample, actual information may differ. Dialog mode: modal ROM Version dialog includes following items: Select ROM version group: List box: The user can select ROM version of phone. OK button (ENTER): The user accepts the selected ROM version.
PAMS Technical Documentation NSM–3/3D Service Software Instructions View Quick/RF Info... command Activation Status Bar Text Alt, V,Q View Quick/RF information. If the NSM–3 phone is in normal mode, the following Quick Info is shown: Dialog mode: modeless If the NSM–3D phone is in normal mode, this Quick Info is shown: Issue 4 02/2002 Nokia Mobile Phones Ltd.
NSM–3/3D Service Software Instructions PAMS Technical Documentation Dialog mode: modeless If phone is in local mode the following RF Information is shown. Information is shown in a modeless dialog which may be left open during other operations. It is also updated when ever needed. Dialog mode: modeless Selections show what data is currently updated by PC. Page 78 Nokia Mobile Phones Ltd.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Phone Information... command Activation Status Bar Text Alt, V,P View Phone Identity. Command opens the Phone Identity Information dialog, which shows identification information. The information is shown in a modeless dialog which may be left open during other operations. It is also updated when ever needed. NSM–3, Dialog mode: modeless Issue 4 02/2002 Nokia Mobile Phones Ltd.
NSM–3/3D Service Software Instructions PAMS Technical Documentation NSM–3D, Dialog mode: modeless Initialization file The After Sales Software includes an initialisation file which has extension .INI. Initialisation file is TESLA.
PAMS Technical Documentation NSM–3/3D Service Software Instructions Call Simulation dialog Monitoring Channel 2 (Monitoring Channel 2 =) Monitoring Channel 3 (Monitoring Channel 3 =) Monitoring Channel 4 (Monitoring Channel 4 =) Monitoring Channel 5 (Monitoring Channel 5 =) Monitoring Channel 6 (Monitoring Channel 6 =) All selections and parameters which are not same as in the RF Controls menu.
NSM–3/3D Service Software Instructions PAMS Technical Documentation This page intentionally left blank. Page 82 Nokia Mobile Phones Ltd.