MJS-59 Module Jig 0770366 The purpose of the MJS-59 mod-
ule service jig is to provide a
method of component-level test-
ing, by applying voltage from an
external power supply when the
phone engine is out of its
mechanics. The engine module
and UI module of RH-10 can be
tested with MJS-59.
RF connection is established
through a replaceable GAC-5
connector. Two SMA-type con-
nectors are available for audio
testing using ADS-7 cables. This
type of connection eliminates
the need for external audio split-
ter.
Note: The nominal supply voltage
for the MJS-59 is +4.1V. The sup-
ply voltage must not exceed
+5.0V.
FPS-8 Flash Prommer 0080321 The Flash Prommer FPS-8 is used
for heavy flash.
Includes ACF-8 AC charger
(0680032).
Includes AXS-4 D9-D9 cable
(0730090).
ADS-6 Audio Cable 0730241 The Audio Cable connects to the
Audio Box JBA-8.
ADS-7 Audio Cable 0730261 ADS-7 Audio Cable is for use
with MJS-59 Module Jig. Audio
is split at the module jig, elimi-
nating the need for a separate
audio box in this configuration.