User Guide

RH-10
System Module CCS Technical Documentation
Page 16 Nokia Corporation Confidential Issue 1 09/2002
Table 5: Slow A/D Converters
Signal name From To Parameter Min Typ Max Unit Function
PA_TEMP Thermistor UEM Input voltage
range
----------------
Input clock freq
0
------- ------
2.741
--------
2.5
V
------
MHz
PA temperature sen-
sor output voltage
Analog Out of RF
PWROUT Robin UEM Input voltage
range
----------------
Input clock freq
0
------- ------
2.741
--------
2.5
V
------
MHz
Buffered output of TX
output detector and
TX power supply
Analog Out of RF
FALSE_DET Robin UEM Input voltage
range
----------------
Input clock freq
0
------- ------
2.741
--------
2.5
V
------
MHz
protection circuit
that is independent
of main transmitter
on-off control circuit
and minimizes the
possibility of false
transmission caused
by component failure
Table 6: RF-BB Analog Signals
Signal name From To Parameter Min Typ Max Unit Function
RX_IP_RF
RX_IN_RF
RX_QP_RF
RX_QN_RF
Batman UEM Differential volt-
age swing (static)
--------------------------
DC level
--------------------------
Input Bandwidth
1.35
--------
1.3
--------
1.4
-------
1.35
-------
1.45
--------
1.4
--------
615
Vpp
-------
V
-------
kHz
Differential in-phase
and quadrature RX
baseband signal
Analog Out of RF
TX_IP_RF
TX_IN_RF
TX_QP_RF
TX_QN_RF
UEM Robin Differential volt-
age swing (static)
---------------------------
DC level
---------------------------
-3 dB Bandwidth
--------
1.65
--------
650
0.9
-------
1.7
-------
1.0
-------
1.75
--------
1950
Vpp
-------
V
-------
kHz
Differential quadra-
ture phase TX base-
band signal for RF
modulator
Analog into RF