Watchdog
MAD4 must reset the CCONT watchdog regularly. CCONT watchdog time can be set
through SIO between 0 and 63 seconds at 1 second steps. After power–up the default
value is 32 seconds. If the watchdog expires, CCONT will cut off all supply voltages. After
total cut–off the phone can be re–started through any normal power–up procedure.
CCONTs watchdog functionality may be temporarily disabled by holding CCONTs
PWRONX/WDDISX pin at logic low.
Power Up
There are four ways to power on the phone.
1. Power Up by Power Button
2. Power Up With Charger Connected
3. Power Up by IBI
VR1_SW RFReg(2) XMIS bias
voltage
200 10 2.67 2.80 2.85
VR2 RFReg(1) Receiver 200 80 2.67 2.80 2.85
VR3 RFReg(0) Synthesizer 200 50 2.67 2.80 2.85
VR4 (CAFE_TX_GATE
AND BAND_SEL)
OR RFReg(3)
Transceiver 200 80 2.67 2.80 2.85
VR5 /BAND_SEL OR
RFReg(4)
TX power
detection
200 80 2.67 2.80 2.85
VR6 RFReg(5) CAFE 200 80 2.67 2.80 2.85
VBB Always on Baseband 200 125 2.67 2.80 2.85
VREF CtrlReg1(1) CCONT, CAFE 30 uVrms 200 uA 1.244
1.478
1.251
1.500
1.258
1.523
VMAD CVReg MAD4 (Core,
MCU, DSP)
N/S
(a)
50 1.30 1.75 2.65
5V Serial data bus Transmitter
N/S
(a)
25 4.8 5.0 5.2
Vpp
_CCONT
CtrlReg1(2) Flash memory
N/S
(a)
25 2.8
4.8
3.0
5.0
3.2
5.2
Output Control signal To
Noise level
(nVrms/℘Hz)
Max
current
(mA)
Range (Voltage)
Min Typ Max