PAMS Technical Documentation 10. Troubleshooting
NSD-5
Issue 1 05/02 Nokia Corporation Page 41
EEPROM for each of these 16 segments. The offset for the segments is computed from
the three-point calibration performed in this test. Then, a second-order approximation is
made and the offset and slope computed.
This tuning is done by putting signal level 1 into the receiver. The RX_IF_AGC will then
automatically adjust for max CAFE input and the RX_IF_AGC is noted. This process is
then repeated for signal levels 2 and 3.
Definition of Result
The results of the three-point tuning are the 16 slope and offset values, which are stored
to EEPROM RF_TUNE_PCS_RX_AGC_OFFSET_SLOPE_HANDLE.
Manual Verification
Use WinTesla as follows: