User Guide

CCS Technical Documentation
Issue 2 11/02 ¤Nokia Corporation Page 63
Set 8th required frequency and level => OK
Set 9th required frequency and level => OK
Typical values and limits in Rx Band Filter Response Compensation EGSM900:
Channel Input frequency (MHz) Measured level difference (dB) Limits (dB)
965 923.26771 -0.118 -10…+5
975 925.26771 0.511 -5…+5
987 927.66771 0.857 -5…+5
1009 932.06771 1.174 -5…+5
37 942.46771 0.569 -5…+5
90 953.06771 1.928 -5…+5
114 957.86771 0.964 5…+5
124 959.86771 0.545 -5…+5
136 962.26771 -0.040 -10…+5
Choose "Stop, write to PM area"