• The phone will send a power ramp sequence at 1950Mhz at 7 different power
levels. The actual signal is at 1950.3MHz, since the transmitter is modulated with
a 300kHz IQ-sinewave.
• Set the analyser to 1950.3MHz 100kHz RBW, sweeptime 2.0 ms, video triggering
used with trace averaging. Set the ref. level first to +25 dBm, then decrease it to
get a more accurate reading when taking a measurement.
• Read power levels for slots from ramp into TXA 2 table and press “Enter” to run
the ramp for 2nd AGC-stage.
• Fill the power levels from the 2nd ramp into TXA 1 table and press “Enter”.
Example shown using an Agilent E4406A