The tuned values are settings for the baseband analog active low pass filters in REX and
TEX ASICs.
WCDMA Temperature Sensor Calibration
This does not require any external instruments.
The phone must be at room temperature for this calibration.
Run this component from the Phoenix menu:
Tunings/WCDMA/Temperature sensor calibration.
This is the initial view. Press “Tune” to run the calibration.
Note: By pressing “Read”, the saved value can be read from PM
The value stored is a DC-voltage from the temperatur sensor in TEX. It’s value is the dif-
ference between the expected value for room temperature so it can be either ±.
WCDMA RX AGC Alignment
A signal generator is needed to provide a test signal into the WCDMA RF test
connector.
Calibration is started from the Phoenix menu:
Tunings/WCDMA/RX AGC Alignment
Save the tuned values into PM
(PM = permanent memory)
Save tuned value
into PM