User Guide

NMM-3 Company Confidential
3 - Service Software CCS Technical Documentation
Page 3-26 Copyright 2003 Nokia Corporation Issue 1 (11/2003)
Company Confidential
Select “OK” for every step/frequency
Repeat the same steps as above for all 9 different frequencies
Typical values and limits in Rx Band Filter Response Compensation EGSM900:
If values are within limits select “Save & Continue” to save values to phone
memory
Channel
Limits
Input frequency
(MHz)
Measured level
d i f f e r e n c e ( d B )
Lower
Limit
(dB)
Upper
Limit
(dB)
965 923.26771 -0.672 -10 +5
975 925.26771 0.109 -5 +5
987 927.66771 0.750 -5 +5
1009 932.06771 0.109 -5 +5
37 942.46771 1.047 -5 +5
90 953.06771 0.109 -5 +5
114 957.86771 0.859 -5 +5
124 959.86771 0.953 -5 +5
136 962.26771 0.328 -10 +5