Additional information for EDGE troubleshooting
EDGE mode troubleshooting differs slightly from basic GSM troubleshooting.
Establish connection to the phone normally (see GSM900/1800 troubleshooting instruc-
tions).
Select product from the menu:
File -> Choose Product -> RH23/RH-33
From toolbar set operating mode to “Local”
Activate RF controls window from the menu:
Testing -> RF Controls
From the RF controls window:
Select Band “GSM900” or “GSM1800” (Default=”GSM900”)
Set Active unit to “Tx” (Default=”Rx”)
Set Edge “On” (Default=”Off”)
Set Operation mode to “Burst” (Default=”Burst”)
Set Tx data type to “Alternate PN9” (Default=”All1”)
Set Rx/Tx channel to 37 on GSM900 or 700 on GSM1800 (Defaults)
Set power level to 8 (Default = 19) on GSM900 or to 2 (Default = 15) on GSM1800
NOTE! For GSM900 Edge power levels 5, 6 and 7 are not in use and for GSM1800 Edge power levels
0 and 1 are not in use.