dialog box.
Figure 28: Call Simulation Panel
Dialog mode: modal
The “Call Simulation” dialog box has following items:
TX Power Level edit box (ALT+T):
All power levels can be selected. This updates same parameter as “TX Power Level” in the
“RF Controls” dialog box. Note that TEST value cannot be selected. If TEST value was in
use when Call simulation menu selected, power level is changed to smallest value.
Channel edit box (ALT+C):
This provides the normal operating RF channel number. Normal GSM/PCS channel num-
bers can be selected.
Same channel is used both for transmission and receiving. This updates same parameter
as “Channel” in the “RF Control” dialog box.
Channel 1,2,3,4,5,6 edit box (ALT+1,2,...):
Channels for monitoring are specified with these six selections. All GSM/PCS channel
numbers can be used. If more than one selection has same number, the monitoring chan-
nel list (neighbor list) will have less than six selected channels. The minimum number of
monitoring channels is one (all channels have same value). The monitoring channel can
also have same value as normal operating channel.
The first monitoring channel updates same the parameter as “Monitoring channel” in the
“RF Controls” dialog box.
Apply button (ALT+A):
Validates and sends entered data to ME.
Set Defaults button (ALT+S):
Sets current values as default Call Simulation values.