User Guide

NSB-5
Service Software PAMS Technical Documentation
Page 50 Nokia Mobile Phones Ltd. Issue 1 03/01
AFC edit box (ALT+F):
This selection allows the user to edit the AFC slope in DAC values.
AGC value is shown only when its value is controlled by PC. When Active Unit has value
RX and Operation Mode is continuous, AGC is controlled by PC except when next adjust-
ment functions are activated:
RSSI Calibration
AFC Diagram
Apply button (ALT+A):
Accepts entered values and validates them. After validation, the application sends corre-
sponding messages to ME, closes the dialog, and updates Info Window.
NOTE: Active Unit and Operation mode are not send with because they are activated
immediately.
Set Defaults button (ALT+S):
Sets the current values as default Rf Control values.
Get Defaults button (ALT+U):
Gets default Rf Controls values as current values.
The next automatic selection is made when Quick testing function is ended:
Active Unit = RX
Update RF Information window
The next table shows the dialog’s properties on different situations:
ACTIVE UNIT = TX:
TX Data Type: Updated
AGC values: Greyed
Monitoring Channel: Greyed
OPERATION MODE = BURST:
TX Power Level: Updated
Continuous Mode Channel: Greyed
Channel: Updated
ACTIVE UNIT = RX:
TX Data Type: Greyed
TX Power Level: BASE, Greyed
Operation Mode = Burst:
AGC values: Greyed
Continuous Mode Channel: Greyed
Channel: Updated
Monitoring Channel: Updated