User Guide

NSB-5
Service Software PAMS Technical Documentation
Page 34 Nokia Mobile Phones Ltd. Issue 1 03/01
Tesla.INI file).
The RX Calibration dialog will be shown when these steps are done. Select the
Save button to save the calibration in the phone.
During tuning, proceed as follows:
-Take care not to damage sensitive measuring instruments with excessive RF power.
-Carry out all tuning steps in the shortest possible time to avoid excessive heating of RF
units.
-Perform all tuning steps in the order presented.
-Never try to mask a fault by tuning it out!
After the tuning has finished, the software reports the following: -AFC init value
-AFC slope
-PSW slope
-AGC DAC values and the corresponding voltages for each gain step (0 - 57dB)
-Limits for the reported values