User Guide

PAMS Technical Documentation Service Software
NSB-5
Issue 1 03/01 Nokia Mobile Phones Ltd. Page 33
Activation Status Bar Text
Alt, T,R Initializing local mode...;
Starts RX calibration.
The next automatic selections are made when this tuning function is activated:
Phone is set to local mode
Update RF information window
The calibration is started automatically when RX calibration is entered.
The calibration is done in the following steps:
User is requested to put signal generator to high input level (read from TESLA.INI
file).
Figure 14: RX Calibration - Set RF High Reference
When the user acknowledges by pressing the OK button, the calibration with
high input level is executed.
User is requested to put signal generator to low input level (read from Tesla.INI
file).
Figure 15: RX Calibration - Set RF Low Reference
When the user acknowledges by pressing the OK button, the calibration with low
input level is executed.
The RX Calibration dialog will be shown when the previous steps are completed.
Select the Save button to store the calibration in the phone.
User is requested to change the signal generator to high input level (Read from