User Guide
PAMS
Technical Documentation
NSE–5
Service Software Instructions
Page 66
Issue 1 07/99
Close button (ENTER):
Clears the display and closes the dialog. To get normal display, set the
phone in normal mode.
Help button (ALT+H):
Context sensitive help.
Call Simulation... command
Activation Status Bar Text
Alt, E, C Initialising local mode
Setting RF Defaults
Call Simulation; Set test on
Command is used for making call simulation. Function opens Call
Simulation dialog.
Dialog mode: modal
Call Simulation dialog has following items:
TX Power Level edit box (ALT+T):
All power levels can be selected. This updates same parameter as TX
Power Level in the RF Controls dialog. Note that TEST value cannot be
selected. If TEST value was in use when Call simulation menu selected,
power level is changed to smallest value.
Channel edit box (ALT+C):
This tells the normal operating RF channel number. Normal GSM/PCN
channel numbers can be selected.