User Guide

PAMS
Technical Documentation
NSE–5
Service Software Instructions
Page 48
Issue 1 07/99
A DC power supply, a service battery and a 3–wire charger calibration
cable is needed for this calibration.
Note: The Energy Management Calibration process in WinTesla should only be used
when the factory calibration for some reason is not any longer valid in the phone. The
factory calibration of the phone energy management parameters are more precise, thus it
is possible to obtain better battery performance, when the calibration has been performed
in the factory.
Activation Status Bar Text
Alt, T,E Initialising local mode...;
The Energy Management Calibration is performed in the following 12
steps:
DC power supply is set to 10.5 Volts.
Mount the service battery on the phone
and
connect the
service battery with the phone by the charger calibration cable.
Connect the service battery to the DC power supply.
Select the menu Tuning and Energy Management Calibration.
The following dialog pop up:
Select OK. The phone is set to local mode, and the energy
management dialog pops up.
Select settings:
2. Battery voltage
3. Charger voltage
4. Battery size
5. Battery temperature
6. Charge current
Press Run. (If also the setting “Save without confirmation” is selected,
then steps 7 to 11 are not applicable.)