User Guide

PAMS
Technical Documentation
NSE–5
Service Software Instructions
Page 34
Issue 1 07/99
The next automatic selections are made when this tuning function is
activated:
Phone is set to local mode
Update RF information window
The calibration is started automatically when RX calibration is entered.
The calibration is done in eleven steps:
User is requested to put signal generator to high input level
(read from .INI file).
When the user acknowledges by pressing OK, the calibration
with high input level is executed.
User is requested to put signal generator to low input level
(read from .INI file).
When the user acknowledges by pressing OK, the calibration
with low input level is executed.
The RX Calibration dialog will be shown when previous steps
are done. Select Save, to store the calibration in the phone.